These templates were created by Gary Novak and Alan Colville, 1989, American Mineralogist, v. 74, p. 488-490.

These templates are a set of Excel spreadsheet programs that calculate unit cell parameters from X-ray diffraction data using a least squares fit procedure. The programs require 2-theta peak positions and your assigned {hkl} indexes for those peaks. There is one template for each of the six crystal systems (hexagonal and trigonal use the same template).

  1. The templates were developed using the Excel spreadsheet programming language.
  2. OPEN the template for the crystal system of interest to you.
  3. Copy the first yellow row (light and dark yellow) down into exactly as many rows as you have indexed peaks ({hkl} values from the book or CD Power Diffraction File indexes).
  4. Replace the example 2-theta and miller index {hkl} values with your own. Enter Miller indices with negative intercepts as negative numbers.
  5. For hexagonal and trigonal minerals, the formal Miller indices usually take the form {hkil}, as compared to {hkl} for the other crystal systems. Because h + k + i = 0, i is not necessary so only h, k, and l are listed in the Power Diffraction File indexes.
  6. The best fit (refined) unit cell parameters are located in the blue area at the bottom of the spreadsheet.
  7. You MUST check your work. The observed and calculated d spacings should be similar, and the delta-d column values should generally be <0.005. Axial lengths should generally be within 0.02 Å of the book values. If your delta-d and axial length accuracy is worse, carefully check the 2-theta angles you entered and your Miller index assignments.